How to replace a disk on a Sun Cluster 3/3.1 cluster with a A5200 array or similar FCAL.
Obviously it's different depending on whether is under SVM or VxVM control.
VxVM[edit]
- Check if the cluster is using 'CVM' (cluster volume manager).
- vxdctl -c mode (If it shows master/slave then CVM is in use, DO OPERATIONS ON MASTER NODE).
- Identify the failed drive
vxdisk -o alldgs list
(note: if the device is 'failing' rather than 'failed' you need to 'remove a disk for replacement' in vxdiskadm first) - On the node hosting the device group: replace the device with luxadm
luxadm replace_device encolsure,position
- On the other node connected to the array: Run
devfsadm
- On either node, reconfigure the DID info
scdidadm -l c#t#d#
thenscdidadm -R d#
(with the did returned from the first command) - On the node hosting the device group,
vxdctl enable
then then 'replace a failed or removed disk' in vxdiskadm
SVM[edit]
- Identify the failed drive
metastat -s setname
(note: if the device is 'failing' rather than 'failed' you need to detach the relevent plexes first) - On the node hosting the device group: replace the device with luxadm
luxadm replace_device encolsure,position
- On the other node connected to the array: Run devfsadm
- On either node, reconfigure the DID info
scdidadm -l c#t#d#
thenscdidadm -R d#
(with the did returned from the first command) - On any node connected to the storage, copy the partition table from the mirrored disk to the new disk
prtvtoc /dev/did/rdsk/workingdisk-s0 | fmthard -s - /dev/did/rdsk/replaceddisk-s0
- On any node connected to the storage, delete and add back any broken metadb's
metadb -s setname
metadb -s setname -d /dev/did/rdsk/replaceddisk-s7
metadb -s setname -a -c 3 /dev/did/rdsk/replaceddisk-s7
- Repair the failed mirror
metareplace -s setname d# -e /dev/did/rdsk/replaceddisk-s0